New feature: The users can now switch between the Spinel and Modbus RTU communication protocols using ModbusConfigurator software.
The thermometer communicates via RS485 using the Spinel or MODBUS RTU protocol. In the case of Spinel protocol, the thermometer can be connected to a joint communication link with other devices of our company – most of our devices communicate via the Spinel protocol. TQS3 can communicate via the binary as well as ASCII format of the Spinel protocol. ASCII format is very simple – the instructions can be sent and the measured values read to/by some of the many terminals for serial communication. For machine processing, it is preferable to use the binary format of the protocol. For both versions, the documentation provides specific examples.
In the case of communication by the MODBUS RTU protocol, the thermometer can be easily integrated into the systems that communicate via this industrial protocol.

Open TQS3 P and demonstration installation on the pipe.
Features
- Thermometer measuring temperatures from -55 to +125 °C.
- 0,1 °C resolution
- Accuracy ±0,5 °C from -10 to +85 °C, otherwise ±2 °C
- Communication line RS485 - up to 32 devices can be connected on a single bus (even more when a repeater is used)
- Thermometer for a pipe temperature measurement
- Spinel or MODBUS RTU communication protocol (to be selected by the user; the factory default setting is the Spinel protocol)
- Low power requirements (typically 2 mA)
- Wago terminal connection
Connections

Example of TQS3 connected to a PC through USB or COM port.

Example of TQS3 connected to a computer network (Ethernet, Internet).
Converter: USB connection is provided by SB485. To connect RS485 to the Ethernet, GNOME485 can be used.
Power: To power all converters and thermometers 12V DC PSU is enough for most cases.
Connection wires: To connect thermometers, power supply and converter, TP cable (Cat5e) is recommended. Use one pair for RS485, and other wires for power supply.
Software: To watch and log the temperatures from TQS3 sensors, Wix software can be used (freeware). Other option is user made software. The protocol is well documented and very simple.

Versions of the TQS3 thermometer (left to right): TQS3 I, TQS3 O, TQS3 P, TQS3 E.
File:
Modbus Configurator - SoftwareModbus Configuration Software
|
451.97 KB | ![]() |
TQS3 P Datasheet |
1.02 MB | ![]() |
Customers who bought this product also bought the following products:
![]() |
TME multi: Temperature and humidity via EthernetA device for measuring temperature and humidity at up to 32 locations. Configuration and preview of all measured values via a website. TME multi is able to send the current values to the server using HTTP GET requests and can also communicate via SNMP and Modbus TCP protocols. When the critical limits are exceeded the system sends e-mail warnings or SNMP traps. 169,44 EUR (20 % VAT incl. excl. Shipping costs) |
This Product was added to our catalogue on Tuesday 09 September, 2014.